Part M Access and Use Dwellings

The Requirement 2022

Share
Part M of the Second Schedule to the Building Regulations, (as amended),
 provides as follows:
Access and Use M1 Adequate provision shall be made for people to access and use a building, its facilities and its
environs.
M2 Adequate provision shall be made for people to approach and access an extension to a building.
Sanitary Facilities M3 If sanitary facilities are provided in a building that is to be extended, adequate sanitary facilities shall be provided for people within the extension.
Changing Places Toilet M4 Where sanitary facilities are provided in a building, or in a building that is to be extended, adequate provision shall be made for people to access and use a changing places toilet, having regard to the use and size of the building.
Non-Application of Part M M5 Part M does not apply to works in connection with extensions to and material alterations of existing dwellings, provided that such works do not create a new dwelling. 
0.1 General
 Part M aims to foster an inclusive approach to the design and construction of the
 built environment. The requirements of Part M (M1 – M5) aim to ensure that
 regardless of age, size or disability:
 In doing so, the Requirements, underpin the principle of Universal Design.
 Universal design is defined in the Disability Act 2005 as “the design and
 composition of an environment so that it may be accessed, understood and used
 to the greatest practicable extent, in the most independent and natural manner
 possible, in the widest possible range of situations and without the need for
 adaptation, modification, assistive devices or specialised solutions, by persons of
 any age or size or having any particular physical, sensory, mental health or
 intellectual ability or disability.”
 Buildings should be designed so that they are easy for people to use and to
 reflect the fact that all people experience changes in their abilities as they
 progress through the different stages of life. It is important for designers to take
 all of the users of buildings into account throughout the design process in order
 to avoid the creation of a built environment that excludes certain groups from
 participating in normal everyday activities.
 Experience has shown that meeting the needs of people with disabilities or
 elderly people frequently generates design solutions which benefit a wider range
 of user groups, including people with young children in buggies, people with
 temporary injuries or carrying heavy luggage.
 This document, Technical Guidance Document M (TGD M), sets out guidance on
 the minimum level of provision to meet requirements M1 - M5.
However, those involved in the design and construction of buildings should also
 have regard to the design philosophy of Universal Design and consider making
 additional provisions where practicable and appropriate. For this purpose, a list
 of useful references, advocating greater accessibility, is given at the end of this
 document. Further advice and guidance can be found at the Centre for
 Excellence in Universal Design, www.universaldesign.ie and in the publication
‘Building for Everyone: A Universal Design Approach (2010 edition).
0.2 The Requirements
 In order to satisfy the requirements of Part M, all buildings should be designed
 and constructed so that:
a
b
0.3 Buildings Other than Dwellings
 In the case of buildings other than dwellings, the building should also be
 designed and constructed so that:
a
b
c
0.4 Dwellings
 Dwellings should be designed and constructed so that:
a
 b
 c
0.5 Use of the Guidance
 Technical Guidance Document M 2022 is divided into 3 sections. Each section
 deals with different types of works.
 Section 1: The guidance in Section 1 sets out the minimum level of provision for
 the following buildings to meet the requirements of M1 to M4:
a
 b
Section 1 applies to both new and existing buildings.
Section 2: The guidance in Section 2 should be read in conjunction with Section
 1 and is intended to provide additional guidance for:
 Section 2 provides additional guidance on the minimum provisions for certain
 elements and features of existing buildings where it is not practicable (refer to
 0.7) to achieve the provisions set out in Section 1.
 Where works (e.g. extensions, material alterations and certain material changes
 of use, etc.) to existing buildings are carried out in accordance with Section 1
 and, where necessary Section 2, this will prima facie indicate compliance with
 Requirement M1.
 Reference should be made to 0.6 and 0.8 for the application of Part M to existing
 buildings and 0.7 for considerations that should be made when determining
 ‘practicability’.
 Section 3: The guidance in Section 3 applies to dwellings and their environs.
 This includes individual dwelling houses and individual apartments. It does not
 apply to the common areas of apartment blocks. The guidance in Section 3 also
 applies to the common areas of duplex buildings.
 0.6 Application of Part M
 The Requirements of Part M apply to:
a: 
 S.I. No. 608 of 2022 amends Part M of the Second Schedule to the Building
 Regulations.
 Under M4, where sanitary facilities are provided in a building, or part of a
 building, adequate provision shall be made for people to access and use a
 changing places toilet, having regard to the use and size of the building
 (refer to 0.6(g)).
b:
 (i) Under M2, adequate provision must be made to approach and access an
 extension. This may be provided by an adequate independent approach2
 and entrance to the extension, or where this is not practicable, the
 existing approach and entrance modified where necessary and where
 practicable, must provide adequate approach and access to the
 extension, and
 (ii) Under M3, where sanitary facilities are provided in a building, adequate
 accessible sanitary facilities must be provided for the people within the
 extension i.e. people using the extension. These may be provided by
 accessible sanitary facilities in the extension or alternatively, those
 facilities in the existing building, modified where necessary, must be
 adequate and accessible from the extension.
 (iii) Under M4, where sanitary facilities are provided in a building, or part of a
 building, that is to be extended, adequate provision shall be made for
 people to access and use a changing places toilet, having regard to the
 use and size of the building (refer to 0.6(g)).
c:
 The Building Regulations apply to any alterations subject to the requirements
 of Part A, B or M.
 This means that alterations to features relevant to compliance with Part M
 e.g. entrances, circulation, etc., must comply with M1.
 The building as a whole, including the approach from the site boundary and
 from on-site car parking where provided, must be no less compliant with M1
 following a material alteration of a building.
 However, this does not mean it is necessary to upgrade the existing access
 to the building entrance unless the entrance itself is subject to a material
 alteration;
d. 
e
f
g
Table 1 Provision of A Changing Places Toilet in New Buildings
0.7 Determination of Practicability
 In the determination of ‘practicability’ with respect to works to an existing
 building, its facilities or its environs the following non-exhaustive list of
 circumstances should be considered.
a
 b
 c
 d
 e
 f
0.8 Existing Buildings
 Building Regulations do not apply to buildings subject to the National Monuments
 Acts 1930 to 2004.
 0.6 sets out the application of Part M to buildings, new and existing.
 The term ‘practicability’ is used in connection with works (e.g. material alterations
 and certain material changes of use) to existing buildings which identifies
 instances where achieving standards of accessibility associated with new
 buildings is not feasible because of particular circumstances. Refer to 0.7 for
 guidance on determining practicability.
 Where works to existing buildings are carried out in accordance with the
 guidance in Section 1 of this document, this will, prima facie, indicate compliance
 with Part M. Where it is not practicable to apply the guidance in Section 1 and
 works are carried out to Section 2, this will also prima facie indicate compliance
 with Part M.
 Works to existing buildings, such as extensions, material alterations and certain
 material changes of use, can present many design challenges because of the
 individual character, appearance and environs of existing buildings. The adoption
 without modification of the guidance in this document may not in all
 circumstances be appropriate. While each existing building and site will present
 its own unique access opportunities and constraints, which may result in different
 ways of addressing accessibility, the fundamental priorities of accessibility should
 be as set out in M1, i.e. accessing and using a building, its facilities and
 environs.
 The application of this Part may pose particular challenges for buildings which
 are of architectural or historical interest. When considering works to an historic
 building, it is important to establish what is important or significant about the
 building. Historic buildings can be significant in many different ways, for example,
 in its physical fabric, in its historical associations or in its archaeological potential.
 The better the understanding of what is important, the easier it will be to design
 appropriate accessible solutions. Information about the significance of a building
 may be obtained from a conservation plan or statement, where these exist, or
 from the architectural conservation officer from the relevant local authority.
Historic buildings include Protected Structures, which are included by each
 Planning Authority on a Record of Protected Structures. These buildings have
 been identified as having particular cultural significance and heritage value.
 As previously stated, the adoption without modification of the guidance in this
 document may not, in all circumstances, be appropriate for historic buildings.
 Liaison with the local Building Control Authority on alternative approaches based
 on the principles contained in this document may be more relevant and should
 be considered. In specific cases, a dispensation or relaxation (or partial
 dispensation or relaxation) of the Requirements may be granted by the local
 Building Control Authority.
 Whilst the provisions of the Building Regulations do not relate to management,
 the role it can play in improving the accessibility of existing buildings is
 acknowledged. Designers/owners should be mindful of this and consider
 enhancing the accessibility of existing buildings through appropriate
 management solutions or compensating for existing buildings that have to apply
 for a (partial) dispensation or relaxation from Part M. For guidance on
 management refer to 0.12.
 For more guidance on historic buildings, refer to:
  Architectural Heritage Protection - Guidelines for Planning Authorities
 Planning Guidelines No. 9 published by the Department of the Environment,
 Heritage and Local Government;
  Advice Series: Access – improving the accessibility of historic buildings and
 places published by the Department of the Environment, Heritage and Local
 Government.
0.9 Fire Safety
 Access provision must be linked to provision for emergency egress in the case of
 a fire. The scope of Part M is limited to matters of access to and use of a
 building. For guidance on means of escape or evacuation, reference should be
 made to Technical Guidance Document B (Fire Safety) and the NDA publication
 ‘Safe Evacuation for All, A Planning and Management Guide, 2011’.
0.10 Diagrams
 Diagrams included in this document are intended to clarify certain aspects of the
 guidance. They are not necessarily to scale and do not represent fully detailed
 solutions. Where dimensions are stated, they refer to minimum or a range of
 finished dimensions. Allowance should be made for all necessary tolerances and
 finishes and on-site deviation. Reference should be made to Technical Guidance
 Document D (Materials and Workmanship) for guidance in relation to
 manufacturing and other tolerances applicable to building components generally.
 0.11 Disability Act 2005
 The Disability Act 2005 aims to advance the participation of people with
 disabilities in everyday life by, for example, improving access to buildings,
 services and information.
 Attention is drawn to the obligation on Public bodies (such as Government
 Departments, Local Authorities, Health Service Executive, Semi-state Bodies,
 etc.) to make their public buildings comply with Part M 2000, by 2015 and Part M
 2010, by 2022.
 It also requires that these public buildings be brought into compliance with
 amendments to Part M not later than 10 years after the commencement of the
 amendment.
 For the purposes of this part of the Disability Act “public building” means a
 building, or that part of a building, to which members of the public generally have
 access and which is occupied, managed or controlled by a public body.
 For the purposes of giving guidance to public bodies on the matter, the National
 Disability Authority has recently initiated the development of a Code of Practice
 for Accessible Public Buildings under Section 25 of the Disability Act.
0.12 Management
 Whilst the provisions of the Building Regulations do not relate to management or
 maintenance and compliance with the Regulations is not dependent on these, it
 is acknowledged that they are important functions and contribute to the ongoing
 accessibility of the building.
maintenance teams include:
  arranging furniture appropriately;
  keeping circulation routes clear, facilities clean, equipment (lifts,
 communication aids, etc.) functioning;
  carrying out maintenance audits on a regular basis;
  conducting staff training and awareness campaigns on peoples specific
 needs and the use of assistive equipment in buildings e.g. maintenance of
 induction loops, hoists and other assistive devices;
  putting a detailed emergency action plan in place to ensure safe egress for
 all in the event of an emergency;
  procurement of accessible goods and services (office furniture, security
 services, etc.);
  providing pre-visit information regarding access to the building on the
 organisation’s website;
  providing information on the accessibility features of the building to
 occupants, in order to allow for effective management procedures to be put
 in place.
 For guidance on managing buildings refer to Building for Everyone: A Universal
 Design Approach (2010 edition), BS 8300:2009, the NDA publication ‘Access
 Handbook Template - A Tool to Help Manage the Accessibility of the Built
 Environment’ and www.nda.ie.
Planning permission Second fix External works Fire safety Accessibility Blocks Air to water heat pump Air to air heat pump Air to ground heat pump IS 440 Time and temperature Zone control Planning Semi detached Fire stopping Fire mastic Fire wraps Fire board Tongue and groove Public liability Building energy rating Fire doors Natural ventilation Vapour control layer Fire cable Underfloor heating pipes Pitch Piling PI Plumbing Plasterboard Employers liability PL Plugs Structurally insulated panels Solar panels Fireline board EL Electric showers Light gauge steel Grant Energy grants Timber frame BER